CFR section

21 CFR 113.40(g)(1)(i)(E): Equipment and procedures

PART 113-THERMALLY PROCESSED LOW-ACID FOODS PACKAGED IN HERMETICALLY SEALED CONTAINERS · Subpart C-Equipment

Key facts

Citation 21 CFR 113.40(g)(1)(i)(E)
Section Equipment and procedures
Part PART 113-THERMALLY PROCESSED LOW-ACID FOODS PACKAGED IN HERMETICALLY SEALED CONTAINERS
Subpart Subpart C-Equipment
Subchapter 21 CFR B Food
Product types cited Food/Cosmetics
Regulation text (excerpt) (E) Differential pressure recorder-controller. When a product-to-product regenerator is used, it shall be equipped with an accurate differential pressure recorder-controller. The differential pressure recorder-controller shall be accurate to within 2 pounds per square inch (13.8 kilopascals). One pressure sensor shall be installed at the sterilized product regenerator outlet and the other pressure sensor shall be installed at the unsterilized product regenerator inlet. The sensor and recorder of…

At a glance

  • 1–9 Inspections citing this section
  • None Warning letters citing this section

Counts are shown as ranges. Exact figures, trends and every underlying record are available in Orca1.

About CFR sections cited by the FDA

Title 21 of the Code of Federal Regulations contains the FDA's regulations, including current good manufacturing practice and quality system requirements that inspections cite.

Source: U.S. Code of Federal Regulations (eCFR); citation statistics from FDA inspection and warning-letter data

Browse all CFR sections cited by the FDA