| Citation | 21 CFR 113.40(f)(7) |
|---|---|
| Section | Equipment and procedures |
| Part | PART 113-THERMALLY PROCESSED LOW-ACID FOODS PACKAGED IN HERMETICALLY SEALED CONTAINERS |
| Subpart | Subpart C-Equipment |
| Subchapter | 21 CFR B Food |
| Product types cited | Food/Cosmetics |
| Regulation text (excerpt) | (7) Bleeders. Bleeder openings 1⁄4-inch (6 millimeters) or larger shall be located at the top of the steam chamber or chambers opposite the point of steam entry. Bleeders shall be wide open and shall emit steam continuously during the entire process, including the come-up time. All bleeders shall be arranged in such a way that the operator can observe that they are functioning properly. |