International safety notice

As a result of a survey conducted by overseas manufacturers, all Trilogy Evo series models are equipped with software that calculates remaining battery power. Due to an issue with the hardware algorithm, one of the following events may occur even when sufficient power is provided: A problem has been identified. (1) When operating on battery power, there is a possibility that the treatment will stop, the power will be lost, and a beeping sound will be generated. (2) If connected to a permanent power source such as an AC power source or an external DC power source, the internal battery may become depleted while continuing treatment. ”Possibility of alarm occurring Please note that this issue may only occur if all of the following conditions are met: ・If the device is operating in CPAP or PSV mode ・If the device cannot detect the patient's breathing effort for at least 10 minutes and 55 seconds. The overseas manufacturer will provide information about the device to users and update the software. vinegar.

Japan / PMDA Recalls · JPN · Jun 24, 2024

Key facts

Title As a result of a survey conducted by overseas manufacturers, all Trilogy Evo series models are equipped with software that calculates remaining battery power. Due to an issue with the hardware algorithm, one of the following events may occur even when sufficient power is provided: A problem has been identified. (1) When operating on battery power, there is a possibility that the treatment will stop, the power will be lost, and a beeping sound will be generated. (2) If connected to a permanent power source such as an AC power source or an external DC power source, the internal battery may become depleted while continuing treatment. ”Possibility of alarm occurring Please note that this issue may only occur if all of the following conditions are met: ・If the device is operating in CPAP or PSV mode ・If the device cannot detect the patient's breathing effort for at least 10 minutes and 55 seconds. The overseas manufacturer will provide information about the device to users and update the software. vinegar.
Regulator Japan / PMDA Recalls
Country JPN
Brand General name: Artificial respirator for adults Sales name: Trilogy Evo series
Manufacturer Philips Japan Co., Ltd.
Models H32565234D9C0, H31744385DC36, H321549862607, H352159314CDE, H291026352000, H35195064AF88, H31680061EE91, H3615646527F3, H2933080353A9, H36169368DF26, H293246313360, H352194199B6D and 14053 more
Date Jun 24, 2024
Regulator page info.pmda.go.jp

At a glance

  • No Recall
  • No Field safety notice

Counts are shown as ranges. Exact figures, trends and every underlying record are available in Orca1.

About International device safety notices

Field safety notices, recalls and safety alerts published by about 30 national medical device regulators outside the United States, matched by Orca1 to FDA device data.

Source: National medical device regulators (as listed), compiled by Orca1

Browse all International device safety notices