International safety notice

As a result of research at overseas manufacturers, all Trilogy Evo series equipped with an oxygen mixing module (Trilo When using FiO2 (ratio of inspired oxygen) set to 70% or higher in G-Evo O2), the oxygen concentration supplied It was confirmed that there is a possibility that the value is less than the allowable error range of -5%. Even if an O2 sensor (a sensor for measuring FiO2 values) is used, the O2 sensor values ​​may not actually be supplied. It was confirmed that there is a possibility that the FiO2 value may be higher than the FiO2 value. It may vary depending on lung resistance, particle filter use, or circuit configuration. The overseas manufacturer will provide information about the device to users and update the software. Therefore, we have decided to take the same action as a voluntary recall in Japan.

Japan / PMDA Recalls · JPN · Aug 1, 2024

Key facts

Title As a result of research at overseas manufacturers, all Trilogy Evo series equipped with an oxygen mixing module (Trilo When using FiO2 (ratio of inspired oxygen) set to 70% or higher in G-Evo O2), the oxygen concentration supplied It was confirmed that there is a possibility that the value is less than the allowable error range of -5%. Even if an O2 sensor (a sensor for measuring FiO2 values) is used, the O2 sensor values ​​may not actually be supplied. It was confirmed that there is a possibility that the FiO2 value may be higher than the FiO2 value. It may vary depending on lung resistance, particle filter use, or circuit configuration. The overseas manufacturer will provide information about the device to users and update the software. Therefore, we have decided to take the same action as a voluntary recall in Japan.
Regulator Japan / PMDA Recalls
Country JPN
Brand General name: Artificial respirator for adults Sales name: Trilogy Evo series
Manufacturer Philips Japan Co., Ltd.
Models H29460649B10D, H358104989449, H29336849D009, H30211635C272, H348433810019, H296831008B8A, H3602538520DC, H29626024863D, H296814694250, H29702523AB70, H286427594A74, H30294923C02C and 4189 more
Date Aug 1, 2024
Regulator page info.pmda.go.jp

At a glance

  • No Recall
  • No Field safety notice

Counts are shown as ranges. Exact figures, trends and every underlying record are available in Orca1.

About International device safety notices

Field safety notices, recalls and safety alerts published by about 30 national medical device regulators outside the United States, matched by Orca1 to FDA device data.

Source: National medical device regulators (as listed), compiled by Orca1

Browse all International device safety notices